HazVent Control System

Turn-key industrial controls for C1D1 / C1D2 extraction.

The GES HazVent Control System integrates gas detectors, alarms, interlocking, illumination, and ventilation control into a single engineered platform. Designed to meet the applicable code requirements in IFC Chapter 39 and NFPA 1 Chapter 38. A Guardian Project Engineer designs your configuration and delivers the engineering shop drawings for permit submittal.

Guardian HazVent control panel — front elevation, deployed in a botanical extraction facility
System Capabilities

Engineered to do what extraction rooms actually need.

A Guardian Project Engineer designs your HazVent configuration to match your facility's process, building layout, and AHJ requirements — and provides the engineering shop drawings required for your permit submittal.

HazVent HMI touchscreen — system diagnostics and operator interface
HMI Touchscreen · Operator interface & system diagnostics
  • Powers up to (10×) 120VAC ceiling lights
  • HMI Touchscreen and system diagnostics
  • Gas detection and alarm sequencing (dual-sensor options)
  • (5×) interlock relays for each system state
  • (3×) programmable digital outputs
  • Remote HazVent Interface
  • VFD fan control for intake and exhaust w/ pressure balancing
  • Variable airflow: base state and purge flow
  • Integrates into building HVAC systems
  • Configurable for new or existing rooms, booths, or pods
  • Input power: 240VAC 1PH 40A
  • Battery backup integrated into every system
Components

A complete platform — every piece engineered for hazardous locations.

Battery Backup

Integrated UPS for PLC, HMI, gas detector, alarms, and (2×) emergency lights. Optional full UPS for fan loads.

Interlock Panels

Motor starter / interlock panels designed to disconnect power to exposed devices during unsafe operating conditions.

IR Gas Detectors

Infrared detectors for the most reliable lifetime accuracy with minimal routine maintenance. Butane, propane, ethanol, heptane, pentane and more.

Alarms

Audible alarms and visual beacons available in C1D1, C1D2, and ordinary location ratings.

Explosion-Proof Lighting

C1D1 / C1D2 ceiling lights sized for your application.

User Inputs

Manual purge push buttons, remote operating switches, explosion-proof outlets in C1D1, C1D2, and ordinary ratings.

Explosion-Proof Fans & Ductwork

AMCA B spark-resistant fans sized to balance at target capture velocities. Motorized dampers, fire dampers, air filters, and duct components.

Code Compliance

Every HazVent control panel is designed to meet the applicable code requirements in IFC Chapter 39 and NFPA 1 Chapter 38, with a complete engineering documentation package for permit submittal.

3rd-party engineering peer review and Professional Engineer stamp can be coordinated through a partner engineering firm when required by your AHJ.