Skip to content
Guardian Extraction Safety
GUARDIAN Extraction Safety
Engineered for Botanical Extraction

Extraction Room Safety, Controls Integration & Booth Retrofits.

Guardian is an engineering systems integrator specializing in gas detection and ventilation safety for botanical and plant oil extraction labs that use flammable solvents. A dedicated Project Engineer designs your gas detection, ventilation controls, alarms, fan logic, interlocks, and code-compliant documentation around your process and building layout.

300+ Lab safety systems designed
2017 Engineering integrator since
Nationwide Coverage across the US
5+ Solvents · IR detection
Core Services

Engineered controls and field-tested support — purpose-built for extraction.

From new C1D1 buildouts to legacy booth modernization, Guardian delivers compliant engineering, integrated controls, and the long-term technical support extraction operators actually need.

HazVent Control System

A turn-key industrial controls package for C1D1 / C1D2 extraction environments.

The GES HazVent Control System integrates gas detection, ventilation, alarm logic, interlocks, and emergency power into a single engineered platform — designed to meet the applicable code requirements in IFC Chapter 39 and NFPA 1 Chapter 38. A Guardian Project Engineer designs your configuration and delivers the engineering shop drawings for permit submittal.

Butane Propane Ethanol Heptane Pentane
System Capabilities 240VAC · 1PH · 40A
  • Powers up to (10×) 120VAC ceiling lights
  • HMI touchscreen with system diagnostics
  • Dual-sensor gas detection & alarm sequencing
  • (5×) interlock relays for each system state
  • (3×) programmable digital outputs
  • VFD intake & exhaust fan control with pressure balancing
  • Variable airflow: base state and purge flow
  • Battery backup w/ optional UPS for fans
  • Integrates into building HVAC systems
  • Configurable per booth, room, or pod

Gas Detectors

Infrared — minimal routine maintenance

Alarms

Audible + visual beacons (C1D1 / C1D2)

Interlocks

Power shutdown to exposed devices

Retrofit Opportunity

Keep your existing extraction room running — safely, compliantly, and on spec.

The extraction industry has evolved. Compliance expectations have changed. Many operating booths were installed years ago — and the systems around them weren't. Guardian helps facilities modernize controls, ventilation, and interlock logic without replacing the whole room.

  • Target

    Older HAL Booths

    Modernize legacy HAL controls with current alarm logic and interlock architecture.

  • Target

    Aging Controllers

    Replace dated controllers with HMI-driven industrial control panels and integrated diagnostics.

  • Target

    Outdated Interlocks

    Upgrade to compliant 5-state interlock logic with documented sequence of operation.

  • Target

    Compliance Catch-Up

    Bring older rooms in line with current IFC Ch. 39 and NFPA 1 Ch. 38 expectations.

Why Facilities Choose Guardian

Engineering authority, written in field hours.

Real-world field experience

Our founders helped build the original HAL Extraction product line and have spent a decade integrating safety systems in real labs.

Retrofit specialization

We treat retrofits as a core practice — not an afterthought. Older infrastructure stays operational and compliant.

Compliance understanding

Guardian engineers code-driven systems against IFC Ch. 39 and NFPA 1 Ch. 38 — with engineered shop drawings sized for your permit submittal.

Long-term support

Bi-annual maintenance, remote engineering, expedited parts, calibration — designed to keep your mission-critical safety system running.

Custom integration capabilities

Every facility is different. We design systems around your booth, room, MEP, and AHJ realities.

Legacy booth support

A lifeline for operators running legacy HAL, ExtractionTek Solutions (ETS), and Precision Extraction booths — OEMs that are no longer in business.

Industries Served

Hazardous-location specialists across the extraction stack.

View all industries
01

Hydrocarbon Extraction

Butane, propane, blended hydrocarbon labs

02

Ethanol Extraction

Ethanol-based solvent processing rooms

03

Solvent Handling

Heptane, pentane, mixed solvent areas

04

Hazardous Processing

C1D1 / C1D2 hazardous location rooms

05

Botanical Processing

Full-facility safety integration

06

OEM Equipment Partners

Integration support for booth manufacturers

Long-Term Support

The team you call when extraction safety systems need real support.

Extraction safety is mission critical. Downtime is costly — unscheduled downtime is catastrophic. Guardian provides scheduled maintenance, immediate remote engineering, and field-tested retrofit services so your lab keeps running and keeps passing inspection.

Bi-Annual

Routine Maintenance Visits

On-site visits every 6 months: gas detector calibration, plenum cleaning, fan tuning, booth inspection, functionality testing, and part replacement recommendations.

Remote

Engineering Support

Annual technical support package for any OEM extraction booth. Phone & video debug, urgent issue resolution, expedited part recommendations.

On-Site

Installation & Retrofits

Two qualified booth technicians, 2–4 days on-site for installation, retrofit, or relocation — to OEM and Guardian HazVent guidelines.

Modernizing an existing extraction room? Planning a new C1D1 facility?

Talk directly to a Guardian Project Engineer. We'll scope your retrofit, walk through your AHJ requirements, or design a turn-key HazVent system around your facility.